Allied Commercial™ KCB048S4BN

Allied Commercial™ K-Series™ | 4 Ton Cooling | 208/230 V | 3 phase | Rooftop Packaged Electric Cooling Unit With Optional Electric Heat

Manufacturer: Allied Air Enterprises
Brand: Allied Commercial™
Part #: 401472
MPN: KCB048S4BN
UPC: 662551504682
CPN:
Min. Order Qty: 1
Qty Order Interval: 1

Recently Viewed

Compressor Type      :      Scroll
Cooling Capacity      :      4 ton
Dimensions      :      47 in W x 85-1/4 in D x 38-7/8 in H
EER Rating      :      11.5
Flow Rate      :      1600 cfm
Fuse Size      :      30 A
IEER Rating      :      14.5
Material      :      Steel
Motor HP      :      1/3 hp Condenser, 3/4, 1-1/2 hp Blower
Motor RPM      :      825 rpm Condenser
Motor Type      :      Direct Drive Blower
Number of Speeds      :      1
Power Source      :      208/230 VAC, 4.1 kW, 3 ph,60 Hz
Refrigerant Type      :      R-410A
SEER Rating      :      14
Series      :      K-Series™
Type      :      Rooftop

Allied Commercial™ Packaged Electric Cooling Unit, Rooftop, Series: K-Series™, 4 ton Cooling, 11.5 EER, 14 SEER, 14.5 IEER, Scroll Compressor, 208/230 VAC, 4.1 kW, 3 ph,60 Hz Power Source, 30 A Fuse, 1600 cfm, R-410A Refrigerant, 1 Speed, Direct Drive Blower Motor, 1/3 hp Condenser, 3/4, 1-1/2 hp Blower Motor, 825 rpm Condenser, Steel, 47 in W x 85-1/4 in D x 38-7/8 in H Dimensions

  • Single-Zone VAV (Variable Air Volume) supply fan technology
  • Up to 61% power savings over comparable units
  • 29% better moisture removal for humidity control when compared to systems with conventional supply fan motors
  • Eco-Last™ Coil System uses up to 52% less refrigerant, is up to 59% lighter, and has up to 20% fewer brazed joints than regular rooftop unit coils (standard on KC and KG models)
  • Isolated compressor for quieter operation and easier service
  • Easy-to-reach gas compartment for quick, simplified diagnostics and serviceability
  • More than 100 field-selectable options ensure fast and easy installation
  • High-pressure switch guards the compressor from extreme operating conditions
  • 2nd generation major design sequence
  • Standard cooling efficiency
  • Belt drive blower
  • (1) 10 in Dia x 10 in W blower wheel
  • (4) 16 x 20 x 2 in disposable filter
  • 20 A minimum circuit
  • Brochure https://7600cgpb-stage.cimm2.com//ASSETS/DOCUMENTS/ITEMS/EN/CGI_ALLIEDCOMMERCIAL_KSERIES.pdf
  • Installation Manual https://7600cgpb-stage.cimm2.com//ASSETS/DOCUMENTS/ITEMS/EN/CGI_ALLIED_KSERIES_KGB-KCB-2-7.5_INSTALLATIONMANUAL.pdf
  • Data/Spec Sheet https://7600cgpb-stage.cimm2.com//ASSETS/DOCUMENTS/ITEMS/EN/CGI_ALLIED_KSERIES_SPECIFICATIONS.pdf

back To Top